The access protoco shall be defined according to the case
Semi anechoic chamber with hybrid absorber and ferrite tile, 7,23 m x 4,83 m x 3,055 (h) m (LxWxH) Internal shield, 3 meter measurement. Radiated emission 30 MHz-1 GHz Pre-Compliant QZ 1,2 x 2,0m. Test volume is cylinder, height is referenced to floor. 30-200 MHz NSA ± 6 dB. 200-1000 MHz NSA ± 4dB. Radiated immunity 80 MHz-1 GHz Compliant TP 1,5 x 1,5 m. Equipment: • Electromagnetic field emission measurement equipment: EMI receiver, antennas, spectrum analyser, LISN, field probes, measurement software. • Electromagnetic field immunity equipment: amplifiers, field probes, antennas, measurement software, transient generators, couplers, EM clamps. • Passive components, filters, ferrites.
• Pre-certification test. • Radiated emission test, 3m distance. EN55022, EN55011, etc. • Radiated immunity test, to 20v/m. EN61000-4-3, 80Mhz – 4,2Ghz. • Conducted emission test. LISNs. EN55011, EN55022, EN55014-1, etc. • EN61000-4-2, EN61000-4-4, EN61000-4-5, EN61000-4-6, EN61000-4-8, EN61000-4-9, EN61000-4-10, EN61000-4-11, EN61000-4-13. • Flicker and harmonics test. • EMC advice and guidance services.
IKERLAN, S.Coop. Pº. J. Mª. Arizmendiarrieta, 2 20500 Arrasate-Mondragón Tél.: +34 943712400 Fax:.+34 943796944
Wide experience (more than 20 years) in test, requirement analysis and development of EMC solutions at concept level, design level and system level. A team of 4 engineers / researchers working full-time on the EMC and electrical safety development and qualification of products. Close to designers EMC consulting. EMC team, design team working in laboratory